Design and installation of fire protection systems 

Fire protection engineering, design, and installation under NFPA, FM Global, and STPS standards.

  • NFPA 11
  • NFPA 13
  • NFPA 14
  • NFPA 20
  • NFPA 22
  • NFPA 72
  • NFPA 96
  • NFPA 2001
  • FM Global
  • NOM-002-STPS-2010
A technician grooves a length of red steel pipe with a pipe groover mounted on its tripod, in the yard of a job site.
FIG. 01 — DESIGN AND INSTALLATION

At CAAF de México®, we conceptualize and plan the fire protection engineering for each project, and we specialize in the installation of eight fixed fire protection systems.

Conceptualization and planning of fire protection engineering in accordance with NFPA and FM Global requirements and the regulations of the STPS (Mexico's Ministry of Labor and Social Welfare).

Efficiency in our designs to optimize materials, design, and project timelines, in accordance with regulatory guidelines and requirements.

The installation services we specialize in are: fire pump rooms, automatic sprinkler systems, foam suppression systems, standpipe and hose systems, clean agent suppression systems, kitchen fire suppression systems, fire water storage tanks, and fire detection and alarm systems.

Scope

What's included

  • Conceptualization and planning of fire protection engineering
  • Design in accordance with NFPA and FM Global requirements and STPS regulations
  • Optimization of materials, design, and project timelines
  • Installation of eight fixed fire protection systems
  • Certified and approved equipment from internationally recognized brands

Process

How we work

  1. Step 01

    Conceptualization

    Formulation of the fire protection engineering for the project.

  2. Step 02

    Design

    Efficient design to optimize materials and project timelines, in accordance with regulatory guidelines and requirements.

  3. Step 03

    Installation

    Installation of the system with certified and approved equipment from internationally recognized brands.

  4. Step 04

    Performance testing

    Tests and diagnostics that validate the correct operation of the system in an emergency.

Systems

Systems this line covers

  • Fire pump room with pumping equipment, a control panel, and red piping labeled “Agua vs incendio” (water vs. fire).
    FIG. 01 — FIRE PUMP ROOM

    NFPA 20

    Fire pump room

    The hydraulic heart of the system: fire pump equipment under NFPA 20.

  • Red automatic sprinkler branch lines installed under a white roof.
    FIG. 01 — SPRINKLER BRANCH LINES

    NFPA 13

    Automatic sprinklers

    Sprinklers that activate with heat to control the fire at its source, under NFPA 13.

  • Red hose cabinet with hose and valve, mounted on a concrete block wall.
    FIG. 01 — HOSE CABINET

    NFPA 14

    Standpipe and hose

    Hose cabinets and hydrant piping for the in-house brigade and the fire department.

  • NFPA 11

    Foam

    Foam to control flammable liquid fires, under NFPA 11.

  • NFPA 2001

    Clean agents

    Waterless extinguishing for rooms with sensitive equipment, under NFPA 2001.

  • Technician in a vest checks the open enclosure of an Ansul system with two agent tanks, in an industrial kitchen.
    FIG. 01 — ANSUL TANKS

    NFPA 96

    Industrial kitchens

    Wet chemical suppression over the hood and cooking appliances, under NFPA 96.

  • Bolted steel fire water tank, completed on site next to the industrial building.
    FIG. 01 — COMPLETED TANK

    NFPA 22

    Water tanks

    The water reserve dedicated to the fire protection system, under NFPA 22.

  • NFPA 72

    Detection and alarm

    Smoke and heat detection and occupant notification, under NFPA 72.

Questions

FAQ about this service line

Both. This service line covers the conceptualization and planning of fire protection engineering in accordance with NFPA and FM Global requirements and STPS regulations, as well as the installation of the fixed systems we specialize in.

We specialize in eight fixed systems: fire pump rooms, automatic sprinklers, standpipe and hose systems, foam suppression, clean agent suppression, industrial kitchen fire suppression, fire water storage tanks, and fire detection and alarm.

Yes. We work with certified and approved equipment from internationally recognized brands, such as Viking, Tyco, Victaulic, Notifier, System Sensor, Ansul, Kidde Fire Systems, and Fike, among others. The FM Approved, UL Listed, and NOM marks belong to each piece of equipment, not to the company that installs it.

Quote

Request quote for design and installation

Fire protection engineering, design, and installation under NFPA, FM Global, and STPS standards. Send us the scope and the location of the building: our team is ready to give you personalized attention and tailored solutions.

WhatsApp
33 2620 1395
Coverage
Zapopan, Jalisco · Nationwide coverage

Approximate area, whether a system is already installed, and whether there is an insurer or Protección Civil (civil protection authority) requirement.

Send via WhatsApp

Preparing the form… in the meantime, you can message us on WhatsApp.

This form is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.